SICOM3216
16+2G¶Ë¿Ú¶þ²ãÍø¹ÜÐÍ¿¨¹ìʽ½»Á÷»ú
²úÆ·¼ò½é

SICOM3216Íø¹ÜÐͽ»Á÷»úÊÇÒ»¿îÂÌÉ«¹¤ÒµÒÔÌ«Íø²úÆ· £¬×î¶àÖ§³Ö2¸öǧÕ×Combo½Ó¿Ú £¬2¸ö¹âµç¿ÉÑ¡°ÙÕ×½Ó¿ÚºÍ14¸ö°ÙÕ×µç¿Ú ¡£SICOM3216Ö§³ÖDT-RingЭÒé×å(×ÔÓúʱ¼ä<50ms) £¬DRP/DHP£¨×ÔÓúʱ¼ä<20ms£© £¬RSTP £¬VLAN £¬×é²¥ £¬QoS¡¢SSH, SSLµÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷ £¬²¢Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ ¡£SICOM3216¾ßÓÐIP40·À»¤µÄ½ðÊôÍâ¿Ç £¬¿¹Ç¿Õñ¶¯µÄ¿¨¹ì×ù £¬-40¡æ-+85¡æ¼«¶ËÇéÐÎζÈ˳ӦÄÜÁ¦¼°ÓÅÒìµÄEMCµç´Å¼æÈÝÐÔÄÜ £¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦ £¬ÏÖÔÚÒÑÆÕ±éÓ¦ÓÃÓÚ·çµç £¬ÅäÍø £¬½»Í¨ £¬Ê¯ÓÍʯ»¯µÈ¹¤ÒµÁìÓò ¡£

Òªº¦ÌØÕ÷

 

ÐÔÄܲÎÊý
Èí¼þ¹¦Ð§
½»Á÷¹¦Ð§ Ö§³ÖVLAN, PVLAN
Ö§³ÖGVRP
Ö§³Ö¶Ë¿Ú¾ÛºÏ
Ö§³Ö¶Ë¿ÚÁ÷¿Ø
Ö§³Ö¶Ë¿ÚÏÞËÙ
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
ÈßÓàÊÖÒÕ Ö§³ÖDT-Ring, DT-Ring+, DT-VLANЭÒé×å, ×ÔÓúʱ¼ä<50ms
Ö§³ÖDRP/DHP,×ÔÓúʱ¼ä<20ms
Ö§³ÖSTP/RSTP
×é²¥ÊÖÒÕ Ö§³ÖIGMP Snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
Çå¾²ÊÖÒÕ Ö§³ÖHTTPs/SSL
Ö§³ÖSSH
Ö§³ÖTACACS+
Ö§³ÖIEEE802.1X
Ö§³Ö¶Ë¿ÚMACµØÖ·°ó¶¨
·þÎñÖÊÁ¿¹ÜÀí Ö§³ÖSP, WRRÐÐÁе÷Àí
¹ÜÀíÓëά»¤ Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨
Ö§³ÖSNMPv1/v2c/v3,¿Éͨ¹ýKyvision¼¯ÖйÜÀí
Ö§³ÖFTP/TFTPÈí¼þÉý¼¶
Ö§³ÖµçÔ´¸æ¾¯,¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯
Ö§³Ö»·Â·¼ì²â
Ö§³ÖCRCÑÚ»¤
Ö§³ÖRMON
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖÏßÀ¹ÊÕϼì²â
Ö§³ÖSyslog
Ö§³ÖLLDP
Ö§³ÖLink-check
IP¹ÜÀí Ö§³ÖDHCP server/snooping/client £¬DHCP Option 82
ʱÖÓ¹ÜÀí Ö§³ÖSNTP Client
²úÆ·¹æ¸ñ
±ê×¼ IEEE 802.3i(10Base-T)
IEEE 802.3u(100Base-TXºÍ100Base-FX)
IEEE 802.3ab(1000Base-T)
IEEE 802.3z(1000Base-SX/LX)
IEEE 802.3x(Á÷¿Ø)
IEEE 802.1p(ÓÅÏȼ¶)
IEEE 802.1Q(VLAN)
IEEE 802.1w(RSTP)
IEEE802.1X
½»Á÷ÊôÐÔ ÓÅÏȼ¶ÐÐÁÐ 4
VLANÊý 256
VLAN ID 1¡«4093
×é²¥×éÊý 256
MAC±í 8K
°ü»º³åÇø 2Mbit
°üת·¢ÂÊ 5.4Mpps
½»Á÷ÑÓ³Ù <5¦Ìs
½Ó¿Ú ǧÕ×¶Ë¿Ú 1000Base-X, SFP½Ó¿Ú; 10/100/1000Base-T(X), RJ45½Ó¿Ú
°ÙÕ×¶Ë¿Ú 100Base-FX, µ¥/¶àÄ£SC/ST/FCÈÎÑ¡; 10/100Base-T(X), RJ45½Ó¿Ú
Console¿Ú Mini USB½Ó¿Ú
¸æ¾¯¶Ë¿Ú 3о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max,2A Max
ָʾµÆ Ç°Ãæ°åָʾµÆ
ÔËÐÐָʾµÆ:Run
¸æ¾¯Ö¸Ê¾µÆ:Alarm
µçԴָʾµÆ:PWR1,PWR2
»·Ö¸Ê¾µÆ:Ring
½Ó¿ÚָʾµÆ:Link/ACT,Speed(µç¿Ú);Link/ACT(¹â¿Ú)
°´Å¥ Reset:Ö§³ÖÖØÆôºÍ»Ö¸´Ä¬ÈÏÉèÖÃ
µçÔ´ ÊäÈëµçѹ 24-48VDC(18-72VDC); 12-24VDC(9-36VDC)
½ÓÈë¶Ë×Ó 5о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó
¹¦ÂÊ <18W
¹ýÔØÑÚ»¤ Ö§³Ö
·´½ÓÑÚ»¤ Ö§³Ö
ÈßÓàÑÚ»¤ Ö§³Ö
»úе½á¹¹ Íâ¿Ç ½ðÊô²ÄÖÊ
É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ
·À»¤Æ·¼¶ IP40
³ß´ç 88mm¡Á135mm¡Á137mm(W¡ÁH¡ÁD)
ÖØÁ¿ 1.25Kg
×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ
ÇéÐÎ ÊÂÇéÎÂ¶È -40¡æ¡«+85¡æ
Öü´æÎÂ¶È -40¡æ¡«+85¡æ
Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶
Öʱ£ MTBF 465000h
±£ÐÞÆÚ 5Äê
ÈÏÖ¤ UL508, Class I Div 2, CE(EMC), FCC: ½ÓÄÉL2:24-48VDCµçÔ´µÄÐͺÅ.
UL508, Class I Div 2: ½ÓÄÉL5:12-24VDCµçÔ´µÄÐͺÅ.
ÐÐÒµ±ê×¼ EMI
FCC CFR47 Part 15,EN55022/CISPR22,Class A

EMS
IEC61000-4-2(ESD) ¡À8kV(contact),¡À15kV(air)
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
IEC61000-4-4(EFT) Power Port:¡À4kV;Data Port:¡À2kV
IEC61000-4-5(Surge) Power Port: ¡À2kV/DM, ¡À4kV/CM; Data Port: ¡À2kV
IEC61000-4-6(CS) 10V(150kHz¡«80MHz)

»úе
IEC60068-2-6(Õñ¶¯)
IEC60068-2-27(¹¥»÷)
IEC60068-2-32(×ÔÓɵøÂä)
»úе³ß´ç

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

ÍƼöÐͺÅ

²úÆ·ÐͺÅ

SICOM3216-Ports-Connector-PS1-PS2

´úÂë½ç˵

´úÂëÑ¡ÐÍ

Ports:¶Ë¿Ú

16T=16×10/100Base-T(X) RJ45µç¿Ú

2S14T=2×100Base-FX,µ¥Ä£¹â¿Ú;14×10/100Base-T(X) RJ45µç¿Ú

2M14T=2×100Base-FX,¶àÄ£¹â¿Ú;14×10/100Base-T(X) RJ45µç¿Ú

2G16T=2×1000Base-X,10/100/1000Base-T(X) Combo½Ó¿Ú;16×10/100Base-T(X) RJ45µç¿Ú

2G2S14T=2×1000Base-X,10/100/1000Base-T(X) Combo½Ó¿Ú;2×100Base-FX,µ¥Ä£¹â¿Ú;14×10/100Base-T(X) RJ45µç¿Ú

2G2M14T=2×1000Base-X,10/100/1000Base-T(X) Combo½Ó¿Ú;2×100Base-FX,¶àÄ£¹â¿Ú;14×10/100Base-T(X) RJ45µç¿Ú

Connector:°ÙÕ×¹â¿Ú²ÎÊý

SC05=SCÌÖÂÛ,¶àÄ£,1310nm,5km

ST05=STÌÖÂÛ,¶àÄ£,1310nm,5km

FC05=FCÌÖÂÛ,¶àÄ£,1310nm,5km

SC40=SCÌÖÂÛ,µ¥Ä£,1310nm,40km

ST40=STÌÖÂÛ,µ¥Ä£,1310nm,40km

FC40=FCÌÖÂÛ,µ¥Ä£,1310nm,40km

SC60=SCÌÖÂÛ,µ¥Ä£,1310nm,60km

SC80=SCÌÖÂÛ,µ¥Ä£,1550nm,80km

NA£ºÎÞ°ÙÕ×¹â¿Úʱ, ConnectorÏîΪ¿Õ

PS1-PS2:ÈßÓàµçÔ´ÊäÈë

L2-L2=24-48VDC(18-72VDC),ÈßÓàÊäÈë

L5-L5=12-24VDC(9-36VDC),ÈßÓàÊäÈë

 

Ñ¡¹ºÅä¼þ

Åä¼þÐͺÅ

Åä¼þ˵Ã÷

ǧÕ×SFPÄ£¿é