SICOM3016ϵÁÐÍø¹ÜÐͽ»Á÷»úÊÇרΪ¹¤ÒµÓ¦ÓÃÁìÓòÉè¼ÆµÄ¸ßÃܶȶ˿ڲúÆ·£¬×î¶àÖ§³Ö4¸ö°ÙÕ×¹â¿ÚºÍ16¸ö°ÙÕ×µç¿Ú¡£Æä½áʵµÄ½ðÊôÍâ¿Ç£¬ÀßÐÔÉ¢ÈÈÉè¼Æ£¬µçÔ´²àµÄ¹ýÁ÷£¬¹ýѹ£¬EMC·À»¤Éè¼Æ£¬ÐźſڵÄEMC·À»¤Éè¼ÆµÈ¹¤ÒµÌØÕ÷£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦¡£SICOM3016Ö§³ÖDT-RingÐÒé×å(×ÔÓúʱ¼ä<50ms)£¬ RSTP£¬VLAN£¬×é²¥£¬QoSµÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷£¬²¢Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2cµÄÍø¹ÜÈí¼þ¡£
Èí¼þ¹¦Ð§ | |
½»Á÷¹¦Ð§ | Ö§³ÖVLAN, PVLAN Ö§³Ö¶Ë¿Ú¾ÛºÏ Ö§³Ö¶Ë¿ÚÁ÷¿Ø Ö§³Ö¶Ë¿ÚÏÞËÙ Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ |
ÈßÓàÊÖÒÕ | Ö§³ÖDT-Ring, DT-Ring+, DT-VLANÐÒé×å, ×ÔÓúʱ¼ä<50ms Ö§³ÖSTP/RSTP |
×é²¥ÊÖÒÕ | Ö§³ÖIGMP Snooping Ö§³ÖGMRP Ö§³Ö¾²Ì¬×é²¥ |
·þÎñÖÊÁ¿¹ÜÀí | Ö§³ÖSP, WRRÐÐÁе÷Àí |
¹ÜÀíÓëά»¤ | Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨ Ö§³ÖSNMPv1/v2c, ¿Éͨ¹ýKyvision¼¯ÖйÜÀí Ö§³ÖFTPÈí¼þÉý¼¶ Ö§³ÖIP/MAC³åÍ»¸æ¾¯, µçÔ´¸æ¾¯, ¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯ Ö§³ÖRMON Ö§³Ö¶Ë¿Ú¾µÏñ Ö§³ÖLLDP Ö§³ÖLink-check |
ʱÖÓ¹ÜÀí | Ö§³ÖSNTP Server/Client |
²úÆ·¹æ¸ñ | |
±ê×¼ | IEEE 802.3i (10Base-T) IEEE 802.3u (100Base-TXºÍ100Base-FX) IEEE802.3x (Á÷¿Ø) IEEE 802.1p (ÓÅÏȼ¶) IEEE 802.1Q (VLAN) IEEE 802.1D(STP) IEEE 802.1w (RSTP) |
½»Á÷ÊôÐÔ | ÓÅÏȼ¶ÐÐÁÐ 4 VLANÊý 256 VLAN ID 1¡«4093 ×é²¥×éÊý 256 MAC±í 8K °ü»º³åÇø 2Mbit °üת·¢ÂÊ 3.0Mpps ½»Á÷ÑÓ³Ù <5¦Ìs |
½Ó¿Ú | °ÙÕ×¶Ë¿Ú 100Base-FX,µ¥/¶àÄ£SC/ST/FCÈÎÑ¡; 10/100Base-T(X), RJ45½Ó¿Ú Console¿Ú RS232,RJ45½Ó¿Ú ¸æ¾¯¶Ë¿Ú 2о3.81mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max,2A Max |
ָʾµÆ | Ç°Ãæ°åָʾµÆ ÔËÐÐָʾµÆ:Run ¸æ¾¯Ö¸Ê¾µÆ:Alarm µçԴָʾµÆ:PWR1,PWR2 ½Ó¿ÚָʾµÆ:Link/ACT,Speed(µç¿Ú);Link/ACT(¹â¿Ú) |
µçÔ´ | ÊäÈëµçѹ 100-240VAC,50/60Hz;220VDC(85-264VAC/120-300VDC); 110VDC(77-154VDC); 24VDC(18-36VDC) ½ÓÈë¶Ë×Ó 3о3.81mm¼ä¾à²åÈëʽ¶Ë×Ó(24VDC); 3о7.62mm¼ä¾à²åÈëʽ¶Ë×Ó(110VDC,220VAC/DC) ¹¦ÂÊ <9.7W ¹ýÔر£»¤ Ö§³Ö ·´½Ó±£»¤ Ö§³Ö ÈßÓà±£»¤ Ö§³Ö(24VDC) |
»úе½á¹¹ | Íâ¿Ç ½ðÊô²ÄÖÊ É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ ·À»¤Æ·¼¶ IP40 ³ß´ç 75mm¡Á165mm¡Á123mm(W¡ÁH¡ÁD) ÖØÁ¿ 1.2Kg ×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ |
ÇéÐÎ | ÊÂÇéÎÂ¶È -40¡æ¡«+85¡æ Öü´æÎÂ¶È -40¡æ¡«+85¡æ Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶ |
Öʱ£ | MTBF 333775h ±£ÐÞÆÚ 5Äê |
ÈÏÖ¤ | ÈÏÖ¤ CE(EMC), FCC: ½ÓÄÉL3:24VDCµçÔ´µÄÐͺÅ. |
ÐÐÒµ±ê×¼ | EMI FCC CFR47 Part 15,EN55022/CISPR22,Class A EMS IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air) IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz) IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À1kV IEC61000-4-5(Surge) Power Port: ¡À1kV/DM, ¡À2kV/CM; Data Port: ¡À1kV IEC61000-4-6(CS) 10V(150kHz¡«80MHz) »úе IEC60068-2-6(Õñ¶¯) IEC60068-2-27(¹¥»÷) IEC60068-2-32(×ÔÓɵøÂä) |
²úÆ·Ñ¡ÐÍ
ÍƼöÐͺÅ
²úÆ·ÐͺŠ|
SICOM3016-Ports-Connector-PS1-PS2 SICOM3016-Ports-Connector-PS1 |
´úÂë½ç˵ |
´úÂëÑ¡ÐÍ |
Ports:¶Ë¿Ú |
4S16T=4×100Base-FX,µ¥Ä£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú 4M16T=4×100Base-FX,¶àÄ£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú 2S16T=2×100Base-FX,µ¥Ä£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú 2M16T=2×100Base-FX,¶àÄ£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú 2S8T=2×100Base-FX,µ¥Ä£¹â¿Ú;8×10/100Base-T(X) RJ45µç¿Ú£¨½öH1ÐͺÅÖ§³Ö£© 2M8T=2×100Base-FX,¶àÄ£¹â¿Ú;8×10/100Base-T(X) RJ45µç¿Ú£¨½öH1ÐͺÅÖ§³Ö£© 1S16T=1×100Base-FX,µ¥Ä£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú 1M16T=1×100Base-FX,¶àÄ£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú 16T=16×10/100Base-T(X) RJ45µç¿Ú |
Connector:°ÙÕ×¹â¿Ú²ÎÊý |
SC05=SCÌÖÂÛ,¶àÄ£,1310nm,5km ST05=STÌÖÂÛ,¶àÄ£,1310nm,5km FC05=FCÌÖÂÛ,¶àÄ£,1310nm,5km SC40=SCÌÖÂÛ,µ¥Ä£,1310nm,40km ST40=STÌÖÂÛ,µ¥Ä£,1310nm,40km FC40=FCÌÖÂÛ,µ¥Ä£,1310nm,40km SC60=SCÌÖÂÛ,µ¥Ä£,1310nm,60km SC80=SCÌÖÂÛ,µ¥Ä£,1550nm,80km NA£ºÎÞ°ÙÕ×¹â¿Úʱ, ConnectorÏîΪ¿Õ |
PS1-PS2:ÈßÓàµçÔ´ÊäÈë |
L3-L3=24VDC(18-36VDC), ÈßÓàÊäÈë |
PS1:µ¥µçÔ´ÊäÈë |
H1=100-240VAC,50/60Hz;220VDC(85-264VAC/120-300VDC),µ¥Â·ÊäÈë H2=110VDC(77-154VDC),µ¥Â·ÊäÈë |
Ñ¡¹ºÅä¼þ
Åä¼þÐͺŠ|
Åä¼þ˵Ã÷ |
DT-BGAZ-05 |
±Ú¹Ò×°Öðå |
DT-FCZ-RJ45-01 |
µ¥¿ÚRJ45·À³¾ÕÖ |