×ðÁú¿­Ê±

²úƷͼƬ²úÆ·¼ò½éÒªº¦ÌØÕ÷ÐÔÄܲÎÊý»úе³ß´ç¶©¹ºÐÅÏ¢×ÊÁÏÏÂÔØ
·¢ËÍѯÅÌ
SICOM3016
20¶Ë¿Ú¶þ²ãÍø¹ÜÐÍ¿¨¹ìʽ½»Á÷»ú
²úÆ·¼ò½é

SICOM3016ϵÁÐÍø¹ÜÐͽ»Á÷»úÊÇרΪ¹¤ÒµÓ¦ÓÃÁìÓòÉè¼ÆµÄ¸ßÃܶȶ˿ڲúÆ·£¬×î¶àÖ§³Ö4¸ö°ÙÕ×¹â¿ÚºÍ16¸ö°ÙÕ×µç¿Ú¡£Æä½áʵµÄ½ðÊôÍâ¿Ç£¬ÀßÐÔÉ¢ÈÈÉè¼Æ£¬µçÔ´²àµÄ¹ýÁ÷£¬¹ýѹ£¬EMC·À»¤Éè¼Æ£¬ÐźſڵÄEMC·À»¤Éè¼ÆµÈ¹¤ÒµÌØÕ÷£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦¡£SICOM3016Ö§³ÖDT-RingЭÒé×å(×ÔÓúʱ¼ä<50ms)£¬ RSTP£¬VLAN£¬×é²¥£¬QoSµÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷£¬²¢Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2cµÄÍø¹ÜÈí¼þ¡£

Òªº¦ÌØÕ÷
ÐÔÄܲÎÊý
Èí¼þ¹¦Ð§
½»Á÷¹¦Ð§ Ö§³ÖVLAN, PVLAN
Ö§³Ö¶Ë¿Ú¾ÛºÏ
Ö§³Ö¶Ë¿ÚÁ÷¿Ø
Ö§³Ö¶Ë¿ÚÏÞËÙ
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
ÈßÓàÊÖÒÕ Ö§³ÖDT-Ring, DT-Ring+, DT-VLANЭÒé×å, ×ÔÓúʱ¼ä<50ms
Ö§³ÖSTP/RSTP
×é²¥ÊÖÒÕ Ö§³ÖIGMP Snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
·þÎñÖÊÁ¿¹ÜÀí Ö§³ÖSP, WRRÐÐÁе÷Àí
¹ÜÀíÓëά»¤ Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨
Ö§³ÖSNMPv1/v2c, ¿Éͨ¹ýKyvision¼¯ÖйÜÀí
Ö§³ÖFTPÈí¼þÉý¼¶
Ö§³ÖIP/MAC³åÍ»¸æ¾¯, µçÔ´¸æ¾¯, ¶Ë¿Ú¸æ¾¯ºÍ»·¸æ¾¯
Ö§³ÖRMON
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖLLDP
Ö§³ÖLink-check
ʱÖÓ¹ÜÀí Ö§³ÖSNTP Server/Client
²úÆ·¹æ¸ñ
±ê×¼ IEEE 802.3i (10Base-T)
IEEE 802.3u (100Base-TXºÍ100Base-FX)
IEEE802.3x (Á÷¿Ø)
IEEE 802.1p (ÓÅÏȼ¶)
IEEE 802.1Q (VLAN)
IEEE 802.1D(STP)
IEEE 802.1w (RSTP)
½»Á÷ÊôÐÔ ÓÅÏȼ¶ÐÐÁÐ 4
VLANÊý 256
VLAN ID 1¡«4093
×é²¥×éÊý 256
MAC±í 8K
°ü»º³åÇø 2Mbit
°üת·¢ÂÊ 3.0Mpps
½»Á÷ÑÓ³Ù <5¦Ìs
½Ó¿Ú °ÙÕ×¶Ë¿Ú 100Base-FX,µ¥/¶àÄ£SC/ST/FCÈÎÑ¡; 10/100Base-T(X), RJ45½Ó¿Ú
Console¿Ú RS232,RJ45½Ó¿Ú
¸æ¾¯¶Ë¿Ú 2о3.81mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max,2A Max
ָʾµÆ Ç°Ãæ°åָʾµÆ
ÔËÐÐָʾµÆ:Run
¸æ¾¯Ö¸Ê¾µÆ:Alarm
µçԴָʾµÆ:PWR1,PWR2
½Ó¿ÚָʾµÆ:Link/ACT,Speed(µç¿Ú);Link/ACT(¹â¿Ú)
µçÔ´ ÊäÈëµçѹ 100-240VAC,50/60Hz;220VDC(85-264VAC/120-300VDC); 110VDC(77-154VDC); 24VDC(18-36VDC)
½ÓÈë¶Ë×Ó 3о3.81mm¼ä¾à²åÈëʽ¶Ë×Ó(24VDC); 3о7.62mm¼ä¾à²åÈëʽ¶Ë×Ó(110VDC,220VAC/DC)
¹¦ÂÊ <9.7W
¹ýÔر £»¤ Ö§³Ö
·´½Ó± £»¤ Ö§³Ö
ÈßÓà± £»¤ Ö§³Ö(24VDC)
»úе½á¹¹ Íâ¿Ç ½ðÊô²ÄÖÊ
É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ
·À»¤Æ·¼¶ IP40
³ß´ç 75mm¡Á165mm¡Á123mm(W¡ÁH¡ÁD)
ÖØÁ¿ 1.2Kg
×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ
ÇéÐÎ ÊÂÇéÎÂ¶È -40¡æ¡«+85¡æ
Öü´æÎÂ¶È -40¡æ¡«+85¡æ
Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶
Öʱ£ MTBF 333775h
±£ÐÞÆÚ 5Äê
ÈÏÖ¤ ÈÏÖ¤ CE(EMC), FCC: ½ÓÄÉL3:24VDCµçÔ´µÄÐͺÅ.
ÐÐÒµ±ê×¼ EMI
FCC CFR47 Part 15,EN55022/CISPR22,Class A

EMS
IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air)
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À1kV
IEC61000-4-5(Surge) Power Port: ¡À1kV/DM, ¡À2kV/CM; Data Port: ¡À1kV
IEC61000-4-6(CS) 10V(150kHz¡«80MHz)

»úе
IEC60068-2-6(Õñ¶¯)
IEC60068-2-27(¹¥»÷)
IEC60068-2-32(×ÔÓɵøÂä)
»úе³ß´ç

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

ÍƼöÐͺÅ

²úÆ·ÐͺÅ

SICOM3016-Ports-Connector-PS1-PS2

SICOM3016-Ports-Connector-PS1

´úÂë½ç˵

´úÂëÑ¡ÐÍ

Ports:¶Ë¿Ú

4S16T=4×100Base-FX,µ¥Ä£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú

4M16T=4×100Base-FX,¶àÄ£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú

2S16T=2×100Base-FX,µ¥Ä£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú

2M16T=2×100Base-FX,¶àÄ£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú

2S8T=2×100Base-FX,µ¥Ä£¹â¿Ú;8×10/100Base-T(X) RJ45µç¿Ú£¨½öH1ÐͺÅÖ§³Ö£©

2M8T=2×100Base-FX,¶àÄ£¹â¿Ú;8×10/100Base-T(X) RJ45µç¿Ú£¨½öH1ÐͺÅÖ§³Ö£©

1S16T=1×100Base-FX,µ¥Ä£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú

1M16T=1×100Base-FX,¶àÄ£¹â¿Ú;16×10/100Base-T(X) RJ45µç¿Ú

16T=16×10/100Base-T(X) RJ45µç¿Ú

Connector:°ÙÕ×¹â¿Ú²ÎÊý

SC05=SCÌÖÂÛ,¶àÄ£,1310nm,5km

ST05=STÌÖÂÛ,¶àÄ£,1310nm,5km

FC05=FCÌÖÂÛ,¶àÄ£,1310nm,5km

SC40=SCÌÖÂÛ,µ¥Ä£,1310nm,40km

ST40=STÌÖÂÛ,µ¥Ä£,1310nm,40km

FC40=FCÌÖÂÛ,µ¥Ä£,1310nm,40km

SC60=SCÌÖÂÛ,µ¥Ä£,1310nm,60km

SC80=SCÌÖÂÛ,µ¥Ä£,1550nm,80km

NA£ºÎÞ°ÙÕ×¹â¿Úʱ, ConnectorÏîΪ¿Õ

PS1-PS2:ÈßÓàµçÔ´ÊäÈë

L3-L3=24VDC(18-36VDC), ÈßÓàÊäÈë

PS1:µ¥µçÔ´ÊäÈë

H1=100-240VAC,50/60Hz;220VDC(85-264VAC/120-300VDC),µ¥Â·ÊäÈë

H2=110VDC(77-154VDC),µ¥Â·ÊäÈë

 

Ñ¡¹ºÅä¼þ

Åä¼þÐͺÅ

Åä¼þ˵Ã÷

DT-BGAZ-05

±Ú¹Ò×°Öðå

DT-FCZ-RJ45-01

µ¥¿ÚRJ45·À³¾ÕÖ

×ÊÁÏÏÂÔØ
ÍøÕ¾µØͼ