×ðÁú¿­Ê±

²úƷͼƬ²úÆ·¼ò½éÒªº¦ÌØÕ÷ÐÔÄܲÎÊý»úе³ß´ç¶©¹ºÐÅÏ¢×ÊÁÏÏÂÔØ
·¢ËÍѯÅÌ
SICOM3008PN
8 ¿ÚȫǧÕ× Íø¹ÜÐÍ Profinet ¿¨¹ìʽ½»Á÷»ú
²úÆ·¼ò½é

SICOM3008PNÍø¹ÜÐÍProfinet½»Á÷»úÖ§³Ö8¸ö°ÙǧÕ××Ô˳Ӧµç¿Ú/2¸öǧÕ×SFPºÍ6¸ö°ÙǧÕ××Ô˳Ӧµç¿Ú¡£SICOM3008PN¾ßÓÐIP30·À»¤µÄ½ðÊôÍâ¿Ç£¬¿¹Ç¿Õñ¶¯µÄ¿¨¹ì×ù£¬-40¡æ-+75¡æ¼«¶ËÇéÐÎζÈ˳ӦÄÜÁ¦¼°ÓÅÒìµÄEMCµç´Å¼æÈÝÐÔÄÜ£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦£¬Í¬Ê±Ìṩ12-58VDCµçÔ´ÊäÈë¡£ÏÖÔڸòúÆ·¿ÉÓÃÓÚ¹¤Òµ×Ô¶¯»¯µÈÁìÓò¡£

Òªº¦ÌØÕ÷
ÐÔÄܲÎÊý
²úÆ·¹æ¸ñ
ÊÖÒÕ²ÎÊý ±ê×¼
IEEE802.3
IEEE802.3u
IEEE802.3ab
IEEE802.3z
IEEE802.3x
IEEE802.1p
IEEE802.1Q
IEEE802.1w
IEEE802.1x
IEEE 802.3az
IEC62439-2
½»Á÷ÊôÐÔ MAC±í 8K
°ü»º³åÇø 4Mbit
°üת·¢ÂÊ 1.5Mpps
½»Á÷ÑÓ³Ù <15us
³¬³¤Ö¡ 9K
½Ó¿Ú °ÙǧÕ××Ô˳Ӧµç¿Ú 100/1000 SFP
10/100/1000Base-T(X), RJ45½Ó¿Ú
Profinet²ÎÊý Profinet°æ±¾ V2.3, V2.32
GSDÎļþ Ö§³Ö
I/O²ÎÊý I/OÑ­»·
Ò»ÖÂÐÔÆ·¼¶ CC-B
MRP MRM&MRC
PNIOÈßÓà Ö§³Ö
Íø¹Ü¹¦Ð§ ½çÃæ
CLI
»ùÓÚWEBµÄÍø¹Ü½çÃæ
SNMP v1,v2,v3, ¿Éͨ¹ýKyvision¼¯ÖйÜÀí
Telnet

¿ìËÙ»Ö¸´»·Ð­Òé
DT-Ring, DT-Ring+, DT-VLANЭÒé×壬×ÔÓúʱ¼ä<50ms
DRP,×ÔÓúʱ¼ä<20ms

ÌìÉúÊ÷ЭÒé
IEEE802.1d STP, IEEE802.1w RSTP, IEEE802.1s MSTP

Á´Â·»ã¾Û¿ØÖÆЭÒéLACP Ö§³Ö

VLANs
256
Port-based VLANs
IEEE 802.1Q tag-based VLANs
IEEE 802.1ad Double Tagging (Q in Q)

×鲥ЭÒé
IGMP v1,v2,v3
GVRP

·ç±©ÒÖÖÆ
×é²¥/¹ã²¥/·ç±©ÒÖÖÆ

Á÷¿ØÖÆ
IEEE 802.3x and Back-Pressure

QoS
IEEE 802.1p QoS
ÓÅÏȼ¶ÐÐÁÐ 8

Çå¾²ÐÔ
HTTPs
SSH

¶Ë¿ÚÇå¾²
»ùÓÚIPºÍMACµÄ»á¼û¿ØÖÆ
IEEE 802.1xÈÏÖ¤µÄÍøÂç»á¼û¿ØÖÆ

¸üкͻָ´
»ùÓÚWEBµÄÊäÈëÊä³öÉèÖÃ
»ùÓÚWEBµÄFirmware¸üÐÂ

Õï¶Ï
ϵͳÈÕÖ¾
VLAN¾µÏñ
ÒÔÌ«ÍøÅþÁ¬Õï¶Ï
Link-check

MIB
RFC 1757 RMON 1,2,3,9
RFC 2674 Q-bridge MIB
RFC-1213 MIB-II
RFC-1493 bridge MIB
RFC 2233 IF MIB

LLDP IEEE 802.1ab
DHCP Ö§³Ö
SNTP/NTP Ö§³Ö

ϵͳ״̬
×°±¸/ÒÔÌ«Íø¶Ë¿Ú״̬
ָʾµÆ Ç°Ãæ°åָʾµÆ
µçԴָʾµÆ:PWR1,PWR2
½Ó¿ÚָʾµÆ:Ethernet port link&Speed
µçÔ´ ÊäÈëµçѹ 12-58VDC
¹¦ÂÊ <9W
½ÓÈë¶Ë×Ó 6о3.81mm¼ä¾à²åÈëʽ¶Ë×Ó
·´½Ó±£»¤ Ö§³Ö
ÈßÓà±£»¤ Ö§³Ö
»úе½á¹¹ Íâ¿Ç ½ðÊô²ÄÖÊ
É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´£¬ÎÞµçÉÈ
·À»¤Æ·¼¶ IP30
³ß´ç 108x154x61mm(W¡ÁH¡ÁD)
ÖØÁ¿ 1.3Kg
×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ
ÇéÐÎ ÊÂÇéÎÂ¶È -40¡æ¡«+75¡æ
Öü´æÎÂ¶È -40¡æ¡«+85¡æ
Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶
Öʱ£ MTBF 463,158Сʱ
±£ÐÞÆÚ 5Äê
ÈÏÖ¤ CE, FCC, Profinet Conformance Class B
ÐÐÒµ±ê×¼ EMI
FCC CFR47 Part 15,EN55022/CISPR22,Class A

EMS
IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air)
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À1kV
IEC61000-4-5(Surge) Power Port:¡À1kV/DM,¡À2kV/CM;Data Port:¡À2kV
IEC61000-4-6(CS) 10V(150kHz¡«80MHz)

»úе
IEC60068-2-6(Õñ¶¯)
IEC60068-2-27(¹¥»÷)
IEC60068-2-32(×ÔÓɵøÂä)
»úе³ß´ç

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

ÍƼöÐͺÅ

²úÆ·ÐͺÅ

SICOM3008PN-Ports-PS1-PS2-PN type

´úÂë½ç˵

´úÂëÑ¡ÐÍ

Ports:¶Ë¿Ú

2GX6GE=2×100/1000Base-X, SFP½Ó¿Ú; 6x10/100/1000Base-T(X)

8GE=8x10/100/1000Base-T(X)

PS1-PS2:ÈßÓàµçÔ´ÊäÈë

L15-L15=12-58VDC,ÈßÓàÊäÈë

PN type

ÎÞ=GSD file

C=GSD file,MRC

M=GSD file, MRC, MRM&System Redundancy

×ÊÁÏÏÂÔØ
ÍøÕ¾µØͼ