²úÆ·¼ò½é

SICOM3000S¶þ²ãÍø¹ÜÐÍ¿¨¹ìʽPoE½»Á÷»ú£¬Ö§³Ö4ǧÕ×¹âÉÏÐж˿ںÍ8¸öǧÕ×PoE¶Ë¿Ú¡£PoE¹¦Ð§Ö§³ÖIEEE802.3afºÍat±ê×¼£¬µçÔ´Ö§³Ö48VDCÊäÈë¡£±¾ÏµÁÐÌṩ¸»×ãµÄPoE¹¦ÂÊÊä³ö£¬×î´ó¿É´ï240W¡£SICOM3000SÖ§³ÖDT-RingЭÒé×å(×ÔÓúʱ¼ä<50ms)£¬DRP/DHP£¨×ÔÓúʱ¼ä<20ms£©£¬STP/RSTP/MSTP£¬VLAN£¬×é²¥£¬QoS£¬SSHµÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷£¬²¢Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ¡£SICOM3000S¾ßÓÐIP40·À»¤µÄ½ðÊôÍâ¿Ç£¬¿¹Ç¿Õñ¶¯µÄ¿¨¹ì×ù£¬¼«¶ËÇéÐÎζÈ˳ӦÄÜÁ¦¼°ÓÅÒìµÄEMCµç´Å¼æÈÝÐÔÄÜ£¬Ê¹¸ÃϵÁвúÆ·¾ß±¸ÔÚ±°ÁÓ¹¤ÒµÇéÐÎÏÂÎȹ̿ɿ¿ÊÂÇéµÄÄÜÁ¦¡£²úÆ·¿ÉÆÕ±éÓ¦ÓÃÓÚ¹¤³§£¬½»Í¨£¬Ê¯ÓÍ»¯¹¤£¬µçÁ¦£¬¹ÜÀÈ£¬»ú³¡£¬³µÕ¾£¬¿Ú°¶µÈ°²·À¼à¿ØϵͳºÍÎÞÏßÍøÂçÁýÕÖÁìÓò¡£

Òªº¦ÌØÕ÷

Ö§³Ö4¸ö100Base-X, 1000Base-X SFP½Ó¿Ú£¬8¸öǧÕ×PoEµç¿Ú

Ö§³ÖIEEE802.3af&at PoE±ê×¼£¬Õû»úÊä³ö¹¦ÂÊ×î´ó240W

Ö§³ÖÈßÓàЭÒ飺DT-Ring(×ÔÓúʱ¼ä<50ms)£¬DRP/DHP£¨×ÔÓúʱ¼ä<20ms£©£¬STP/RSTP/MSTP

Ö§³ÖÇå¾²ÊÖÒÕ£ºHTTPS/SSL£¬SSH£¬TACACS+£¬IEEE802.1X£¬RADIUS£¬Óû§·Ö¼¶£¬¶Ë¿Ú¸ôÀë

Ö§³ÖCLI¡¢Telnet¡¢Web¶àÖÖ¹ÜÀí·½·¨ÒÔ¼°»ùÓÚSNMPv1/v2c/v3µÄÍø¹ÜÈí¼þ

Ö§³ÖDDM

IP40·À»¤Æ·¼¶

ÐÔÄܲÎÊý
Èí¼þ¹¦Ð§
½»Á÷¹¦Ð§ Ö§³ÖVLAN
Ö§³ÖGVRP
Ö§³Ö¶Ë¿Ú¾ÛºÏ, LACP
Ö§³Ö¶Ë¿ÚÁ÷¿Ø
Ö§³Ö¶Ë¿ÚÏÞËÙ
Ö§³Ö¶Ë¿Ú·ç±©ÒÖÖÆ
ÈßÓàÊÖÒÕ Ö§³ÖDT-Ring, DT-Ring+, DT-VLANЭÒé×壬×ÔÓúʱ¼ä<50ms
Ö§³ÖDRP/DHP,×ÔÓúʱ¼ä<20ms
Ö§³ÖSTP/RSTP/MSTP
×é²¥ÊÖÒÕ Ö§³ÖIGMP Snooping
Ö§³ÖGMRP
Ö§³Ö¾²Ì¬×é²¥
Çå¾²ÊÖÒÕ Ö§³ÖHTTPS/SSL
Ö§³ÖSSH
Ö§³ÖTACACS+
Ö§³ÖIEEE802.1X
Ö§³ÖRADIUS
Ö§³ÖÓû§·Ö¼¶
Ö§³Ö¶Ë¿Ú¸ôÀë
Ö§³ÖIP Source Guard
·þÎñÖÊÁ¿¹ÜÀí Ö§³ÖQoS, 802.1p(CoS), DSCP
Ö§³ÖSP, WRRÐÐÁе÷Àí
Ö§³ÖACL
¹¤ÒµÐ­Òé Ö§³ÖEtherNet/IP
Ö§³ÖModbus/TCP
¹ÜÀíÓëά»¤ Ö§³ÖConsole, Telnet, WEB¹ÜÀí·½·¨
Ö§³ÖSNMPv1/v2c/v3£¬¿Éͨ¹ýKyvision¼¯ÖйÜÀí
Ö§³ÖFTP/TFTP/HTTP·½·¨Èí¼þÉý¼¶
Ö§³ÖFTP/TFTP/HTTP·½·¨ÉèÖÃÎļþÉÏ´«ÏÂÔØ
Ö§³ÖµçÔ´¸æ¾¯, IP/MAC³åÍ»¸æ¾¯, ÄÚ´æ/CPUʹÓÃÂʸ澯, ¶Ë¿Ú¸æ¾¯, »·¸æ¾¯, ¶Ë¿ÚÁ÷Á¿¸æ¾¯, CRC¼°¶ª°üÂʸ澯, SFP½Ó¿ÚÎüÊչ⹦Âʸ澯ºÍ·¢Ë͹⹦Âʸ澯£¬Î¶ȸ澯
Ö§³ÖDDM (SFP½Ó¿Ú)
Ö§³Ö»·Â·¼ì²â
Ö§³ÖRMON
Ö§³Ö¶Ë¿Ú¾µÏñ
Ö§³ÖSyslog
Ö§³ÖLLDP
Ö§³ÖLink-check
Ö§³ÖIPv4/IPv6
IP¹ÜÀí Ö§³ÖDHCP server/snooping/client, DHCP Option 82
Ö§³ÖARP
ʱÖÓ¹ÜÀí Ö§³ÖSNTP Client
Ö§³ÖNTP Client
Ö§³ÖʱÇøºÍÏÄÁîʱÉèÖÃ
·ÓÉ Ö§³Ö¾²Ì¬Â·ÓÉ
PoE¹ÜÀí Ö§³ÖPoE¶Ë¿ÚÉ趨, PD¼ì²â
Ö§³ÖPoE¶Ë¿Ú¹©µçÓÅÏȼ¶¹ÜÀí
Ö§³ÖPoE״̬ÅÌÎʼ°¸æ¾¯£¬Ô¶³Ì¹ÜÀí
²úÆ·¹æ¸ñ
ÊÖÒÕ²ÎÊý ±ê×¼
IEEE 802.3i (10Base-T)
IEEE 802.3u (100Base-T and 100Base-FX)
IEEE 802.3ab (1000Base-T)
IEEE 802.3z (1000Base-SX/LX)
IEEE 802.3ad (Á´Â·¾ÛºÏ)
IEEE 802.3x (Á÷¿Ø)
IEEE 802.1p (ÓÅÏȼ¶)
IEEE 802.1Q (VLAN)
IEEE 802.1d (STP)
IEEE 802.1w (RSTP)
IEEE 802.1s (MSTP)
IEEE 802.1x (Network Access Control)
IEEE 802.1ab (LLDP)
IEEE 802.3af PoE
IEEE 802.3at PoE+
½»Á÷ÊôÐÔ ÓÅÏȼ¶ÐÐÁÐ 8
VLANÊý 4094
VLAN ID 1¡«4093
×é²¥×éÊý 511
MAC±í 8K
°ü»º³åÇø 4.1Mbit
°üת·¢ÂÊ 17.9Mpps
½»Á÷ÑÓ³Ù <5¦Ìs
³¬³¤Ö¡³¤¶È 10000 bytes
½Ó¿Ú ǧÕ׶˿Ú
100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú
10/100/1000Base-T(X), RJ45½Ó¿Ú
IEEE 802.3af/at PoE¶Ë¿Ú£¬Ã¿¸öPoE¶Ë¿ÚÊä³ö¹¦ÂÊ×î´ó15/30W
Òý½Å1¡¢2ΪV+£¬Òý½Å3¡¢6ΪV-£¨End-Span PSE£©
Console¿Ú RS232,RJ45½Ó¿Ú
¸æ¾¯¶Ë¿Ú 3о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max, 2A Max
ָʾµÆ Ç°Ãæ°åָʾµÆ
ÔËÐÐָʾµÆ:Run
¸æ¾¯Ö¸Ê¾µÆ:Alarm
µçԴָʾµÆ:PWR1,PWR2
½Ó¿ÚָʾµÆ:Link/ACT, Speed(µç¿Ú); Link/ACT, Speed(¹â¿Ú)
PoEָʾµÆ: POE1- POE8
°´Å¥ Reset:Ö§³ÖÖØÆôºÍ»Ö¸´Ä¬ÈÏÉèÖÃ
µçÔ´ ÊäÈëµçѹ
48VDC(18-57VDC)
18-45VDC ÊÊÓÃÓÚ·ÇPoE
45-57VDC ÊÊÓÃÓÚPoE(802.3af)
51-57VDC ÊÊÓÃÓÚPoE+(802.3at)
½ÓÈë¶Ë×Ó 4о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó
PoE¹¦ÂÊÊä³ö ×î´ó240W
¹¦ÂÊ <11W
¹ýÔر£»¤ Ö§³Ö
·´½Ó±£»¤ Ö§³Ö
ÈßÓà±£»¤ Ö§³Ö
»úе½á¹¹ Íâ¿Ç ½ðÊô²ÄÖÊ
É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´,ÎÞµçÉÈ
·À»¤Æ·¼¶ IP40
³ß´ç70mm¡Á135mm¡Á110mm (W¡ÁH¡ÁD)
ÖØÁ¿1.0Kg
×°Ö÷½·¨ DIN¿¨¹ìʽ»ò±Ú¹Òʽ
ÇéÐÎ ÊÂÇéÎÂ¶È -40¡æ¡«+75¡æ
Öü´æÎÂ¶È -40¡æ¡«+85¡æ
Ïà¶Ôʪ¶È 5¡«95%ÎÞÄý¶
Öʱ£ MTBF 488963h
±£ÐÞÆÚ 5Äê
ÈÏÖ¤ CE, FCC
EMC: EN 55032/35, EN 61000-6-4, EN 61000-6-2
Rail Traffic: EN 50121-4
ÐÐÒµ±ê×¼ EMI
FCC CFR47 Part 15,EN55032/CISPR22,Class A
EMS
IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air)
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À1kV
IEC61000-4-5(Surge) Power Port:¡À1kV/DM,¡À2kV/CM;Data Port:¡À1kV
IEC61000-4-6(CS) 10V(150kHz¡«80MHz)
»úе
IEC60068-2-6(Õñ¶¯)
IEC60068-2-27(¹¥»÷)
IEC60068-2-32(×ÔÓɵøÂä)
»úе³ß´ç

×ðÁú¿­Ê±¡¤(ÖйúÇø)ÈËÉú¾ÍÊDz«!

¶©¹ºÐÅÏ¢

²úÆ·Ñ¡ÐÍ

²úÆ·ÐͺŠÊä³ö½Ó¿Ú µçÔ´
SICOM3000S-4GX8GP-L16-L16 4×100Base-X, 1000Base-X, 10/100/1000Base-T(X) SFP½Ó¿Ú; 8×10/100/1000Base-T(X) RJ45 PoEµç¿Ú  48VDC (18-57VDC)£¬ÈßÓàÊäÈë

 

Ñ¡¹ºÅä¼þ

Åä¼þÐͺÅ

Åä¼þ˵Ã÷

SFPÄ£¿é

²Î¿¼¹¤Òµ¼¶SFPÄ£¿éÑ¡¹º±í

DT-BGAZ-02

±Ú¹Ò×°Öðå

DT-FCZ-RJ45-01

µ¥¿ÚRJ45·À³¾ÕÖ

 

×ÊÁÏÏÂÔØ
ÍøÕ¾µØͼ